Log In
New user? Click here to register. Have you forgotten your password?
NC State University Libraries Logo
    Communities & Collections
    Browse NC State Repository
Log In
New user? Click here to register. Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Cavanaugh, Curtis"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • No Thumbnail Available
    An Adaptive Electronic Interface for Gas Sensors
    (2002-01-22) Cavanaugh, Curtis; H. Troy Nagle, Chair; Edward Grant, Member; Mark White, Member
    This thesis focuses on the development of an adaptive electronic interface for gas sensors that are used in the NC State electronic nose. We present an adaptive electronic interface that allows for the accurate mapping of the sensor's voltage output to sensor resistance profiles. The adaptive interface uses a linearized Wheatstone bridge in a constant current configuration. The balancing of the bridge and the adjustment of the subsequent gain stage is performed using programmable variable resistors. The programmable resistors are controlled by a LabVIEW® program. The same control program also determines and records all the resistor values in the interface circuit. The resistance of each sensor is accurately computed by LabVIEW® using the interface-circuit, resistor values, and the voltage output of the circuit. Compensating for sensor drift can be done in LabVIEW® by adjusting the programmable resistor values so that a zero-voltage output is produced during the reference cycle. By doing this zero adjustment between each 'sniff' of an odorant, the baseline drift can be minimized.A single channel of the adaptive electronic interface has been designed and tested. The interface can be calibrated so that it is 99% accurate when performing sensor resistance measurements. A new conducting polymer sensor chamber has also been designed and tested. The new radial flow sensor chamber was minimizes the dead volume in the chamber and also deliver the odorant to each sensor at the same time. Two operating modes were compared: continuous-flow and sniff-and-hold. Both modes gave good classification performance while testing four different coffee samples. Experimental testing indicates that sensor response is highly correlated with the sample flow rate. Future work to more fully characterize this correlation is recommended.

Contact

D. H. Hill Jr. Library

2 Broughton Drive
Campus Box 7111
Raleigh, NC 27695-7111
(919) 515-3364

James B. Hunt Jr. Library

1070 Partners Way
Campus Box 7132
Raleigh, NC 27606-7132
(919) 515-7110

Libraries Administration

(919) 515-7188

NC State University Libraries

  • D. H. Hill Jr. Library
  • James B. Hunt Jr. Library
  • Design Library
  • Natural Resources Library
  • Veterinary Medicine Library
  • Accessibility at the Libraries
  • Accessibility at NC State University
  • Copyright
  • Jobs
  • Privacy Statement
  • Staff Confluence Login
  • Staff Drupal Login

Follow the Libraries

  • Facebook
  • Instagram
  • Twitter
  • Snapchat
  • LinkedIn
  • Vimeo
  • YouTube
  • YouTube Archive
  • Flickr
  • Libraries' news

ncsu libraries snapchat bitmoji

×