The Performance of Passive Lumped Element

Show simple item record

dc.contributor.advisor Dr. Michael B. Steer, Committee Chair en_US
dc.contributor.advisor Dr. David Schurig, Committee Member en_US
dc.contributor.advisor Dr. Paul D Franzon, Committee Member en_US
dc.contributor.author Heo, Seung Kyun en_US
dc.date.accessioned 2010-08-19T18:19:55Z
dc.date.available 2010-08-19T18:19:55Z
dc.date.issued 2010-04-30 en_US
dc.identifier.other etd-04022010-093745 en_US
dc.identifier.uri http://www.lib.ncsu.edu/resolver/1840.16/6340
dc.description.abstract Lumped elements are the most widely used passive components in Radio Frequency (RF) circuits. The characteristics variation over change in frequency, however, limits their application. This limitation stems from the physical dimensions of lumped elements, which are, in general, 0603, 0402, and 0201 size in order to avoid the phase shift between the input and the output. By examining the Quality Factor (Q) and Self-Resonant Frequency (SRF), the performance of lumped elements can be determined. The quality factor contains the energy storing and dissipation terms, which vary according to frequency. This quality factor can be obtained using the S-parameters of lumped elements. It is difficult to obtain accurate measurement of a non-coaxial package device such as a lumped inductor, because it cannot be measured using a calibrated measurement system. A Print Circuit Board (PCB) fixture is thus considered to connect a Device Under Test (DUT) to 50 ohm connectors, and the effects of the fixture are then removed by performing a user fixture standards calibration. The combination of a port extension and calibration using a manufacturer’s calibration kit is employed to collect one-port S-parameters. The best result is achieved using a SubMiniature version A (SMA) fixture that has a short line and good impedance matching This thesis presents an extraction method to derive the quality factor of lumped elements, and the quality factor is obtained using one-port S-parameters. en_US
dc.rights I hereby certify that, if appropriate, I have obtained and attached hereto a written permission statement from the owner(s) of each third party copyrighted matter to be included in my thesis, dis sertation, or project report, allowing distribution as specified below. I certify that the version I submitted is the same as that approved by my advisory committee. I hereby grant to NC State University or its agents the non-exclusive license to archive and make accessible, under the conditions specified below, my thesis, dissertation, or project report in whole or in part in all forms of media, now or hereafter known. I retain all other ownership rights to the copyright of the thesis, dissertation or project report. I also retain the right to use in future works (such as articles or books) all or part of this thesis, dissertation, or project report. en_US
dc.subject Lumped Element en_US
dc.subject SRF en_US
dc.subject Quality Factor en_US
dc.title The Performance of Passive Lumped Element en_US
dc.degree.name MS en_US
dc.degree.level thesis en_US
dc.degree.discipline Electrical Engineering en_US