Implementation of Microwave Measurements Using Novel Calibration Techniques
| dc.contributor.advisor | Dr. Michael B. Steer, Committee Chair | en_US |
| dc.contributor.advisor | Dr. Douglas Barlage, Committee Member | en_US |
| dc.contributor.advisor | Dr. Griff Bilbro, Committee Member | en_US |
| dc.contributor.author | Goswami, Aditya | en_US |
| dc.date.accessioned | 2010-04-02T17:56:06Z | |
| dc.date.available | 2010-04-02T17:56:06Z | |
| dc.date.issued | 2003-05-19 | en_US |
| dc.degree.discipline | Computer Engineering | en_US |
| dc.degree.level | thesis | en_US |
| dc.degree.name | MS | en_US |
| dc.description.abstract | NetA (Network Analysis) tools for calibration of microwave measurements has been implemented. NetA contains calibration and de-embedding procedures as data analysis MATLAB routines. The Through Line method for calibration of two ports has been used and the NetA process flow has also been explained. Complex characteristic impedance of the micro-strip transmission line has been calculated using the ETRL (Enhanced TRL)technique. Results have been simulated using NetA tools. A LabVIEW Implementation of NetA has also been implemented so as to enhance the usability of NetA and also provide the capability of Real--time microwave calibration and de-embedding. | en_US |
| dc.identifier.other | etd-05192003-110822 | en_US |
| dc.identifier.uri | http://www.lib.ncsu.edu/resolver/1840.16/492 | |
| dc.rights | I hereby certify that, if appropriate, I have obtained and attached hereto a written permission statement from the owner(s) of each third party copyrighted matter to be included in my thesis, dissertation, or project report, allowing distribution as specified below. I certify that the version I submitted is the same as that approved by my advisory committee. I hereby grant to NC State University or its agents the non-exclusive license to archive and make accessible, under the conditions specified below, my thesis, dissertation, or project report in whole or in part in all forms of media, now or hereafter known. I retain all other ownership rights to the copyright of the thesis, dissertation or project report. I also retain the right to use in future works (such as articles or books) all or part of this thesis, dissertation, or project report. | en_US |
| dc.subject | microwave measurements | en_US |
| dc.subject | through-line | en_US |
| dc.subject | en_US | |
| dc.subject | TL | en_US |
| dc.subject | NetA | en_US |
| dc.subject | Calibration | en_US |
| dc.subject | Microwave | en_US |
| dc.title | Implementation of Microwave Measurements Using Novel Calibration Techniques | en_US |
Files
Original bundle
1 - 1 of 1