Measuring dinitrogen gas emissions from a lagoon treatment system

dc.contributor.advisorDr. Sarah Liehr, Committee Co-Chairen_US
dc.contributor.advisorDr. Wayne Robarge, Committee Memberen_US
dc.contributor.advisorDr. John Classen, Committee Co-Chairen_US
dc.contributor.authorLarsen, Julie Melissaen_US
dc.date.accessioned2010-04-02T17:59:31Z
dc.date.available2010-04-02T17:59:31Z
dc.date.issued2004-04-05en_US
dc.degree.disciplineBiological and Agricultural Engineeringen_US
dc.degree.levelthesisen_US
dc.degree.nameMSen_US
dc.description.abstractA method for collecting dinitrogen gas emissions from open pond waste treatment systems was developed. The method was critically tested in a laboratory for sources of air contamination to ensure reliable gas measurements. A laboratory experiment was done to estimate the rate at which dissolved dinitrogen would be stripped out of solution due to non-dinitrogen bubbles rising through the water column. A volumetric mass transfer coefficient for the process was estimated for clean water. The gas collection method was implemented in a partially aerated lagoon treatment system for dinitrogen and methane gas sampling. The volumetric mass transfer coefficient found in the laboratory for clean water was adjusted to compensate for field gas production rates, temperatures and wastewater quality to estimate the rate of stripped dinitrogen from the partially aerated lagoon. The estimated rate of stripped dinitrogen was subtracted from the total measured dinitrogen flux to estimate the dinitrogen produced biologically. Results from laboratory testing revealed that dinitrogen can be measured with low amounts of dinitrogen atmospheric contamination (0.57% N₂) and the preliminary field results suggest that biological denitrification did occur at this lagoon treatment system.en_US
dc.identifier.otheretd-01052004-223912en_US
dc.identifier.urihttp://www.lib.ncsu.edu/resolver/1840.16/921
dc.rightsI hereby certify that, if appropriate, I have obtained and attached hereto a written permission statement from the owner(s) of each third party copyrighted matter to be included in my thesis, dissertation, or project report, allowing distribution as specified below. I certify that the version I submitted is the same as that approved by my advisory committee. I hereby grant to NC State University or its agents the non-exclusive license to archive and make accessible, under the conditions specified below, my thesis, dissertation, or project report in whole or in part in all forms of media, now or hereafter known. I retain all other ownership rights to the copyright of the thesis, dissertation or project report. I also retain the right to use in future works (such as articles or books) all or part of this thesis, dissertation, or project report.en_US
dc.subjectdenitrificationen_US
dc.subjectdinitrogenen_US
dc.subjectgas measurementen_US
dc.subjectwaste treatment systemsen_US
dc.titleMeasuring dinitrogen gas emissions from a lagoon treatment systemen_US

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
etd.pdf
Size:
559.15 KB
Format:
Adobe Portable Document Format

Collections