Energy Modeling and Analysis of the WRCNC Building on NCSU's Centennial Campus

dc.contributor.advisorDr. James W. Leach, Committee Memberen_US
dc.contributor.advisorDr. Herbert M. Eckerlin, Committee Chairen_US
dc.contributor.advisorDr. Stephen D. Terry, Committee Memberen_US
dc.contributor.authorMendon, Vrushalien_US
dc.date.accessioned2010-04-02T18:15:41Z
dc.date.available2010-04-02T18:15:41Z
dc.date.issued2009-12-02en_US
dc.degree.disciplineMechanical Engineeringen_US
dc.degree.levelthesisen_US
dc.degree.nameMSen_US
dc.descriptionNorth Carolina State University Theses Mechanical and Aerospace Engineering.;North Carolina State University Theses Mechanical and Aerospace Engineering.
dc.description.abstractThis study compares the actual and projected energy consumption for the Wildlife Resources Commission’s North Carolina headquarters building located on the Centennial Campus of the North Carolina State University and, suggests a new strategy for applying LEED ratings to the energy performance of buildings. In the initial part of the study, monthly building energy consumption data from August 2005 to May 2009 and energy-saving measures taken by the building mechanical engineers from March 2007 to October 2008 are recorded. When compared with the early design energy use projections, the actual energy consumption was still much higher. In the second part of the study, a detailed energy model of the building reflecting changes made to the building was built and simulated using EnergyPlus. The results were then compared to the actual energy consumption of the building. According to ASHRAE Guideline 14-2002, the EnergyPlus model is considered calibrated. Thus, it is suggested that energy models used by LEED for rating purposes need to be verified and a more accurate rating system adopted, one that places emphasis on actual energy consumption rather than solely on projections.en_US
dc.formatThesis (M.S.)--North Carolina State University.
dc.identifier.otheretd-11052009-144154en_US
dc.identifier.urihttp://www.lib.ncsu.edu/resolver/1840.16/2594
dc.rightsI hereby certify that, if appropriate, I have obtained and attached hereto a written permission statement from the owner(s) of each third party copyrighted matter to be included in my thesis, dis sertation, or project report, allowing distribution as specified below. I certify that the version I submitted is the same as that approved by my advisory committee. I hereby grant to NC State University or its agents the non-exclusive license to archive and make accessible, under the conditions specified below, my thesis, dissertation, or project report in whole or in part in all forms of media, now or hereafter known. I retain all other ownership rights to the copyright of the thesis, dissertation or project report. I also retain the right to use in future works (such as articles or books) all or part of this thesis, dissertation, or project report.en_US
dc.subjectEnergyPlusen_US
dc.subjectEnergy modelingen_US
dc.subjectEnergy Analysisen_US
dc.titleEnergy Modeling and Analysis of the WRCNC Building on NCSU's Centennial Campusen_US
dcterms.abstractKeywords: EnergyPlus, energy modeling, energy Analysis.
dcterms.extentix, 160 pages : illustrations (some color), maps (some color), plans (some color)